Consumable supplies
- EEG electrode gels for use with active electrodes in head-caps
- Electrode pastes for use with flat-type active electrodes for EEG without a head-cap (conductive + adhesive in one product)
- Electrode gels and creams for use with flat-type active electrodes for ECG and EMG (must be used with double-sided adhesive tape)
- Syringes to inject gel into head-cap electrode holders
- Double-sided adhesive electrode rings for use with flat-type active electrodes
- Other consumable items you might find useful
Gels, creams, and pastes are available from a wide variety of sources, but we carry quite a few options and we have tested their performance across a range of conditions. Here we present a summary of the products we recommend.
NOTE: you should always use the same electrolyte on the CMS and DRL electrodes, reference electrodes and electrodes at all measurement sites. In case you are measuring EEG at the same time as ECG and/or EMG, you will need to use an electrolyte formulated for EEG on the ECG / EMG electrodes. This may necessitate some amount of skin preparation to achieve optimal contacts on peripheral sites, since electrolytes for EEG tend not to be as effective on their own at reducing the impedance of dry skin as may be found on the exposed skin of the forearm, for example.
EEG electrode gels for use with active electrodes in head-caps #
- Signagel® Electrode Gel (Parker Laboratories, Inc.) is the recommended electrolyte for most biopotential measurement applications. Signagel contains an adequate, but relatively low salt concentration, which makes it mild for use on sensitive skin. As a polymer, Signagel remains conductive for hours, and it is bacteriostatic. Thus, the unused product does not separate or degrade over time, which means it has a long shelf life. The product is manufactured and packaged under the strictest conditions, resulting in consistent quality and safety. It is also conveniently packaged in a clear tube with a tip that fits nicely into the back of a 10-20 cc syringe used for gel application. One disadvantage of Signagel is that it becomes less viscous as it is warmed by the body, so in case the participant’s hair holds the cap away from the scalp and the electrolyte needs to bridge the gap, Signagel may not be the best choice. In that case, consider an alternate electrolyte that is less heat sensitive.
- Signacreme® Electrode Cream (Parker Laboratories, Inc.) is a highly conductive, cosmetic-quality cream electrolyte that enjoys many of the same quality advantages as Signagel, but due to its creme formulation it retains its viscosity even as it warms to body temperature. Signacreme’s packaging is less convenient for dispensing into syringes, so you may want to consider transferring the product into a different vessel for convenient syringe filling.
- Electro-Gel® (Electro-Cap International, Inc.) works well, but has a short shelf life and is inconveniently packaged.
- Redux® Creme (Parker Laboratories, Inc.) works well, but less conductive than Signacreme.
Electrode pastes for use with flat-type active electrodes for EEG without a head-cap (conductive + adhesive in one product) #
- Tensive® Conductive Adhesive Gel (Parker Laboratories, Inc.)
- Ten20® Conductive Paste (Weaver and Company)
Electrode gels and creams for use with flat-type active electrodes for ECG and EMG (must be used with double-sided adhesive tape) #
- Redux® Creme
- Signacreme® Electrode Cream
#
Conductivity measures relative to 1M saline #
| Product | Conductivity Relative to 1M Saline |
| 1 M Saline | 100% |
| Redux® Electrolyte Paste (Parker) | 86% |
| Normal (0.154 M) Saline | 80% |
| Electro-Gel® (Electro-Cap) | 77% |
| Signagel® (Parker) | 69% |
| Signacreme® (Parker) | 66% |
| Elefix® (Nihon Kohden) | 66% |
| Redux® Electrolyte Creme (Parker) | 66% |
| g.GAMMAgel (g.tec) | 63% |
| Ten20® Paste (D.O Weaver) | 43% |
| Skin Conductance Paste (Lykken & Venables formula) | 29% |
| Distilled Water | 0% |
Viscosity rankings relative to 1M saline #
| Elefix (Nihon Kohden) | High |
| Ten20 Paste (D.O Weaver) | High |
| Redux® Electrolyte Paste (Parker) | Medium |
| Signacreme (Parker) | Medium |
| Redux® Electrolyte Creme (Parker) | Medium |
| Skin Conductance Paste | Medium |
| Signagel (Parker) | Low |
| Gamma Gel (g.tec ) | Low |
| Electro-Gel (Electro-Cap) | Low |
| 1 M Saline |
#
Syringes to inject gel into head-cap electrode holders #
- MonoJect syringe with integrated curved plastic tip – This one-piece plastic syringe is affordable and convenient to use. Experimenters who work with younger participants report that the plastic tip is less anxiety provoking than a standard Luer-Lok syringe with a metal blunt needle. Cost per participant is comparable.
- 10, 20, or 30 cc Luer-Lok syringes – Use with a 15 or 16 gauge blunt-tipped needle.
Double-sided adhesive electrode rings for use with flat-type active electrodes #
- 12 mm od x 4 mm id, double sided adhesive rings – These small adhesive rings are best used when space is limited, but the small adhesive area means they do not stick as well as the larger 19×4 mm rings.
- 19 mm od x 4 mm id, double sided adhesive rings – These rings are best used with the flat-type active electrodes. They have a large surface area for robust adhesion. The inner diameter is approximately the same size as the electrode contact on the flat-type electrodes. The outer diameter will extend well beyond the outer boundary of the electrode housing, but this provides improved adhesion to the skin.
Note: Avoid using alcohol to prep the skin before applying adhesives to the body, because this will strengthen the bond of the adhesive. Also note that the longer these rings are in contact with the skin, the more robust the bond. With alcohol prep and prolonged contact, it is conceivable that injury could result upon removal.
Other consumable items you might find useful #
- Deionized water – In regions with hard water (high in minerals), you may benefit from using deionized water with table salt to balance electrode offsets and for testing / troubleshooting. Because the exposure time for washing is brief, even relatively hard tap water may be just fine for washing the electrodes and caps. Hard water will often have a murky or it will have a reddish brown color, and it is often associated with a scaly residue on sinks, faucets and other fixtures.
- NaCl (non-iodized table salt) – Mixed with water for electrode balancing and for testing / troubleshooting. NaCl in solution ensures that there is ample free Chloride in the water so that the ionic charge at each electrode will balance over time. After 3-5 minutes of soaking a set of active electrodes in salt water, offsets should begin to balance and move toward zero. Don’t expect the offsets to reach zero. It is most important that the offsets are less than +-40 mV across all electrodes and that they are stable.
Any electrodes with high offsets that do not yield to soaking in salt water may indicate a contaminated electrode pellet. In this case, inspect the electrode contact for discoloration. Normal sintered Ag/AgCl electrodes should be a dingy gray / brown color, and contamination may be associated with a white or orange powder build-up. In this case, you may find it necessary to use a soft toothbrush to very lightly abrade the electrode contact to remove the build-up and then soak again.
If the electrode contacts are shiny Silver, this indicates the Chloride at the tip of the electrode has been stripped by some means. In this case, soaking in salt water will not solve the problem, and you may observe that the shiny Silver electrodes are noisier than others with the normal coloration. This can happen over the course of several years with normal use, but if it happens sooner, then it may be the result of improper handling. Most often this happens when electrodes are washed with soap, soaked in water without NaCl on a regular basis, or when harsh chemicals are used for cleaning or disinfection.
- Medical tape – Use 3M Micropore paper tape to hold electrodes or leads in place. Avoid cloth (Durapore) or transparent (Transpore) tape, as these tapes leave residues on the cables and on clothing. Avoid using any kind of tape to bundle leads together, since tape residue on cables will attract dirt and eventually will become black and unsightly.
- Activated Hydrogen Peroxide solution – Clorox Healthcare Hydrogen Peroxide disinfectant solution is available from Cortech Solutions. This disinfectant is safe for the electrodes and does not require a vent hood, unlike many liquid disinfectant solutions. It is EPA-registered for use on soft surfaces. Simply spray it on and let air dry per label instructions. It will kill bacteria on soft surfaces, including electrodes and head caps, in just 30 seconds. It is the fastest non-bleach disinfecting times available (based on 30-second bacteria and virus contact times for disinfecting on Federal master labels of leading Healthcare wipes as of 10/2011. Use as directed on hard, nonporous surfaces.) This product has excellent product aesthetics – no chemical fumes or odors for patient and staff comfort. It has fast kill times on 43 microorganisms, including those that cause more than 75% of all HAIs.
We recommend disinfecting any surfaces that come into contact with the participant or the electrode gel, including the head-cap, chin/neck strap, electrodes, and the first few inches of the electrode cables after each use. Disinfection should be done AFTER washing and towel or air-drying the equipment so that residual water from washing does not dilute the disinfectant.
Note that we do not recommend Metricide by Metrex for use with ActiveThree. This product accelerates loss of Chloride from electrodes, drying/cracking of lead-wire insulation and bleaching of electrode/head-cap labels and requires a vent hood, which is rarely available in an electrophysiology lab.