View Categories

Head-caps

Table of Contents

The ActiveThree head cap was developed in cooperation with Dr. Peter Praamstra at the Behavioral Brain Sciences Center, University of Birmingham, United Kingdom. The head cap consists of an elastic cap with plastic electrode holders. The cap itself does not contain electrodes – only plastic electrode holders that receive the pin-type active electrodes. The caps have ear-slits for easy access to the ears. Head-caps are provided with an elastic / velcro chin strap for fixing the cap in place, but body harnesses with criss-cross chest straps are also available.  The fabric template of the standard caps is suitable for positioning electrodes at traditional 10/20 positions, although a variety of electrode position layouts and labeling schemes are available.

Sizes and layouts #

Caps are available in a wide range of sizes and with a variety of electrode position layouts.  The age/gender norms and maximum number of electrode sites for various sizes of caps are outlined below.

SizeColorHead Circ.Max # SitesStd. LayoutMalesFemales
Infa 6Red22-26 cm3210/20premature infants
Infa 5Blue26-30 cm3210/20premature infants
Infa 4Yellow30-34 cm3210/20premature infants
Infa 3Brown34-38 cm6410/200-1 mo.0-1.5 mo.
Infa 2/3Brown / Pink36-40 cm6410/200-2 mo..5-3 mo.
Infa 2Pink38-42 cm6410/201-3.5 mo.1.5-5.5 mo.
Infa 1/2Pink / Light Blue40-44 cm6410/202-6.5 mo.3-9 mo.
Infa 1Light Blue42-46 cm6410/203.5-10.5 mo.5.5-15.5 mo.
Infa 1 / Extra SmallLight Blue / Green44-48 cm6410/206.5-19 mo.9-28 mo.
Extra SmallGreen46-50 cm12810/20 or ABC10.5->36 mo.15.5->36 mo.
Extra Small / SmallGreen / Yellow48-52 cm12810/20 or ABC19->36 mo.28->36 mo.
SmallYellow50-54 cm25610/20 or ABCtoddlers / children
Small / MediumYellow / Red52-56 cm25610/20 or ABCchildren / teens / young adults
MediumRed54-58 cm25610/20 or ABCteens / adults
Medium / LargeRed / Blue56-60 cm25610/20 or ABCteens / adults
LargeBlue58-62 cm25610/20 or ABClarge teens / adults
Extra LargeBrown62-66 cm25610/20 or ABCvery large adults

Standard cap layouts for 16, 32 and 64 channels are based on the International 10/20 System.  

Layouts for 128 channel caps are available in an expanded 1020 system based on Oostenveld and Praamstra, The five percent electrode system for high-resolution EEG and ERP measurements. Clinical Neurophysiology 112 (2001) 713-719 (see black circles and open circles, excluding dots, depicted in figure 2 on p 4).  

Biosemi’s standard head cap layout for caps with 128, 160 and 256 channels have electrode positions that are arranged in rings that are at equal and descending altitude with respect to the vertex (appearing in a flat projection to be concentric rings at consistent radius from the vertex, sometimes termed “equiradial”).  The electrode position coordinates of standard ActiveThree head caps are available from https://www.biosemi.com/download.htm. Below are top views of the 32, 64, 128, 160 and 256 channel layouts.

32 channel layout

32 Channels

64 channel layout

64 Channels

128 channel layout – expanded 1020

128 1020 5 percent layout
128 1020 5 percent layout

128 channel layout – equiradial positions

128 Channels

160 channel layout – equiradial positions

160 Channels

256 channel layout – equiradial positions

256 Channels